Table 12.250 Public Improvements
Unofficial copy. It may be out of date. Not legal or zoning advice. Zoning rules change, and only the city or county can say for sure what is allowed on a property. Confirm with the city or county planning department before you buy, sign or build.
The official Lehi code is at https://www.lehi-ut.gov/government/codes-ordinances/development-code/.
Text pulled 2026-10-19 from this source.
Tables (like use tables) may not copy cleanly, so check any table against the official code.
Confirm anything here with Lehi planning before you rely on it.
TABLE 12.250
PUBLIC IMPROVEMENT REQUIREMENTS
(Amended 07/09/02; 03/26/13)
Development and RURAL-3 ACRE RURAL-3 ACRE RURAL-1 ACRE RURAL-1 ACRE URBAN LOT NON-
Improvement LOT LOT LOT LOT LESS THAN 1 RESIDENTIAL
Requirements
(Single lot only) (Subdivision) (Single lot only) (Subdivision) ACRE NEW
Minimum lot size (Single lot and DEVELOPMENT
(after ROW 3 Acres or Zoning 3 Acres or Zoning 1 Acre 1 Acre Subdivision)
dedication) District District (Single lot and
Requirement of Subdivision)
Required Frontage requirement requirement Zoning District Requirement of
on dedicated hard (whichever is (whichever is Zoning District
surface road greater) greater) Zone District lot
width requirement
Dedicated Street Zone District lot Zone District lot Zone District lot Zone District lot Zone District lot
and Trail Right of width requirement width requirement width requirement width requirement width requirement YES
Way (see note 5)
YES YES YES YES YES Per DSPIS (see
Required asphalt note 4)
width for new Per DSPIS Road-4 Per DSPIS (see Per DSPIS (see
street note 4) note 4) YES
N.A. Standard Detail. N.A.
Provide City YES
Culinary and (see note 4)
Pressure Irrigation YES
N.A. See note #3 N.A. YES YES
Water YES
Infrastructure See note #1 See note #2 See note #1 See note #1 and #2 YES
YES
Provide City YES YES YES YES YES
Sewer
N.A. (unless N.A. (unless
Infrastructure
affected by new YES affected by new YES YES
Provide City
Power improvements) improvements)
Infrastructure YES (Entire YES (Entire
Relocation of Frontage, or 300’ YES Frontage, or 300’ YES YES
Existing Power
Poles and Other minimum) minimum)
Utilities
Construct
sidewalks
Construct Curbs N.A. N.A. N.A. YES YES YES
and Strip Paving
Provide Plat for N.A. YES N.A. YES YES for two (2) or YES for two (2) or
Recordation more lots more lots
Notes:
1. Connection to the City sewer is required if City lines are within 300 feet of any part of the subject lot. Add an additional 150 feet for each lot in the subdivision.
Lots, which are not required to connect to the City sewer system, must comply with the applicable State and County regulations prior to applying to Lehi City.
2. The developer is required to install sewer main lines with service laterals to each lot in any new street regardless of whether or not connection to the City sewer
system is required.
3. Required if City main lines are within 500 feet of any part of the subject lot. Add an additional 250 feet for each lot in the subdivision.
4. (DSPIS) = Lehi City Design Standards and Public Improvement Specifications.
5. No construction is allowed in areas designated for future roads in Master Transportation Plan or trails in the Parks and Trails Master Plan.
6. Escrow or Letter of Credit Bond and Public Improvement Agreement are required for all public and private improvements per Section 11.220.
Lehi City Development Code Page 12-37
12.250 Neighborhood Exchange Structures · Table 12.260 Animal Rights