10-6-12 MINIMUM PARKING REQUIREMENTS

Unofficial copy. It may be out of date. Not legal or zoning advice. Zoning rules change, and only the city or county can say for sure what is allowed on a property. Confirm with the city or county planning department before you buy, sign or build. The official Wendover code is at https://wendovercityutah.com/planning-%26-zoning. Text pulled 2026-10-19 from this source. Tables (like use tables) may not copy cleanly, so check any table against the official code. Confirm anything here with Wendover planning before you rely on it.
1. Shared parking. The zoning administrator may authorize a reduction in the total number of required parking spaces for two or more uses jointly providing off-street parking when their respective hours of peak operation do not overlap. Shared parking shall be subject to the following conditions: 2. Computation: The number of shared spaces for two or more distinguishable land uses shall be determined by the following procedure: a) Multiply the minimum parking required for each individual use, as set forth in Table 6.4 by the appropriate percentage indicated in Table 6C shared parking calculations, for each of the six designated time periods. b) Add the resulting sums for each of the six columns. c) The minimum-parking requirement shall be the highest sum among the six columns resulting from the above calculations. d) Select the time period with the highest total parking requirement and use that total as the shared parking requirement. 3. Other uses. If one or all of the land uses proposing to make use of shared parking facilities do not conform to the general land use classifications in Table 6C, shared parking calculations, as determined by the zoning administrator, then the applicant shall submit sufficient data to indicate the principal operating hours of the uses. Based upon this information, the zoning administrator shall determine the appropriate shared parking requirement, if any, for such uses. 4. Process. As a part of the Zoning application shared parking shall be submitted on a form approved by the zoning administrator. Table 6C Shared Parking Percentages General Land Use Classification Office Retail Sales and Services Restaurant (not 24 hour) Theater Guest Rooms Restaurant / Lounge Conference Rooms Religious Institution 1:00 AM – 7:00 AM 5% 0% 20% 0% 100% 40% 0% 0% Weekdays 7:00 AM – 6:00 PM 100% 70% 70% 60% 55% 60% 100% 25% 6:00 PM – 1:00 AM 5% 100 100% 100% 100% 100% 100% 50% 1:00 AM – 7:00 AM 0% 30 100% 0% 100% 50% 0% 0% Weekends 7:00 AM – 6:00 PM 15% 75 75% 80% 55% 45% 100% 100% 6:00 PM – 1:00 AM 60% 100 90% 100% 100% 100% 100% 50% Table 6D Parking Requirements Use Athletic Club, Sports Club / Health Spa Bank, Walk-In Only Bank, Walk-In with Drive-Up Boarding / Rooming House Bowling Alley Church Cleaning Services, Testing or Repair of Materials of Commodities. Community Centers or Recreation Building Daycare Facility Dwelling, Multi-Unit Dwelling, Single Living Unit Elderly-Disabled Housing / Nursing Home and Assisted Living Facility Furniture / Carpet / Appliance Store Gas Station Hospital Library, Art Gallery and Museum Parking Requirements 4.37 spaces per 1,000 sq ft of gross floor area 0.63 spaces per 1,000 sq ft of gross floor area 4.23 spaces per 1,000 sq ft of gross floor area 1 Space for each room for rent, + 2 additional spaces if a portion of the building is used as a single dwelling unit. 2.36 spaces per lane 1.25 spaces for each 6 ft of linear pew or 4 seats. However: a) Where a church building is designed or intended to be used by two congregations at the same time, parking of 2.25 parking spaces shall be provided for each 6 ft of linear pew or 4 seats; b) For buildings designed or intended to be used for conferences or other special meetings involving more than the regular congregations, the necessary parking shall be recommended by the Planning Commission and determined by the City Council. 1 space for each 3 employees 4 spaces per 1,000 sq ft of gross floor space 1 space for every 2 employees, + 2 additional parking spaces, + 1 loading space for every 8 clients 1.5 spaces for each residential unit. 2 spaces for each residential unit 1 space for each 3 dwelling units 1.22 spaces per 1,000 sq ft of gross floor area 2 spaces for each 2 employees, excluding spaces to serve gas pumps 1.79 spaces per bed 2 spaces for each 1,000 sq ft of gross floor area Light Industrial / Manufacturing (Wholesale stores, repair shops for household equipment and radio and television, and repair establishment) Machinery Sales Office, General Office, Government Office, Medical / Dental Care Paint / Home Improvements / Hardware Store Private Club and Lodge Production and Manufacturing Building Public Utility and Public Services Use Fast Food Restaurant, Restaurant, Bar, Cafeteria and other eating and drinking places with less than 21 seats Fast Food Restaurant, Restaurant, Bar, Cafeteria and other eating and drinking places with 21 or more seats Quality / Family Restaurant, cafeteria and Bar / Lounge Retail Sales Store, Personal Service Establishment, Shoe Repair, Barber and Beauty Store, etc. School, Elementary, Jr. High or Boarding (except High) High School Supermarket Theater and Auditorium Warehousing or Storage Building (not to include self storage) Warehousing or Storage of Uses NOT elsewhere classified Other Uses: 1.59 spaces per 1,000 sq ft of gross floor space 2.1 spaces per 1,000 sq ft floor area 2.79 spaces per 1,000 sq ft floor area 3.84 spaces per 1,000 sq ft floor area 4.11 spaces per 1,000 sq ft floor area 3.29 spaces per 1,000 sq ft floor area 1 space for each room for rent, + 1 space for each 100 sq ft gross floor area + 1 space for each 4 employees 1.59 spaces per 1,000 sq ft floor area 1 space for each 3 employees + 5 spaces for public use 0.5 spaces per seat 14.14 spaces per 1,000 sq ft of gross floor area 15.89 spaces per 1,000 sq ft of gross floor area 4.1 spaces per 1,000 sq ft of gross floor area 1 space for each 3 employees + 5 spaces 0.19 spaces per student 3.42 spaces per 1,000 sq ft floor area 0.26 spaces per seat 0.5 spaces per 1,000 sq ft of gross floor area 1 space per 1,000 sq ft of gross floor area For any other use not specifically mentioned or provided for in this Section, the zoning administrator or secretary shall determine the standards to be applied for parking, using as a guide the listed use which most closely resembles the use propose.

10-6-11 RECREATIONAL VEHICLES USED AS DWELLING STRUCTURES · 10-6-13 ACCESS REQUIREMENTS FOR OTHER THAN RESIDENTIAL LOTS

Ask a broker about Wendover zoning, free

CallTextFree summary